To configure Private VLAN in the web interface:
1. Click add new Private VLAN configuration.
2. Specify the Private VLAN ID and Port Members.
3. Click Save.
Figure 3-10.5.1: The Port Isolation Configuration
Parameter description:
Delete:
Check to delete a private VLAN entry. The entry will be deleted during the next save.
Private VLAN ID
The ID of this particular private VLAN.
Port Members
A row of check boxes for each port is displayed for each private VLAN ID. To include a port in a Private VLAN, check the
box. To remove or exclude the port from the Private VLAN, make sure the box is unchecked.
Adding a New Private VLAN
Click to add a new private VLAN ID. An empty row is added to the table, and the private VLAN can be configured as
needed. The allowed range for a private VLAN ID is the same as the switch port number range. Any values outside this
range are not accepted, and a warning message appears. Click "OK" to discard the incorrect entry, or click "Cancel" to
return to the editing and make a correction.
The Private VLAN is enabled when you click "Save".
Port Isolation
Port Isolation provides for an apparatus and method to isolate ports on layer 2 switches on the same VLAN to restrict
traffic flow. The apparatus comprises a switch having said plurality of ports, each port configured as a protected port or
a non-protected port. An address table memory stores an address table having a destination address and port number
pair. A forwarding map generator generates a forwarding map which is responsive to a destination address of a data
packet. The method for isolating ports on a layer 2 switch comprises configuring each of the ports on the layer 2 switch
as a protected port or a non-protected port. A destination address on an data packet is matched with a physical address
on said layer 2 switch and a forwarding map is generated for the data packet based upon the destination address on
the data packet. The data packet is then sent to the plurality of ports pursuant to the forwarding map generated based
upon whether the ingress port was configured as a protected or non-protected port.
This page is used for enabling or disabling port isolation on ports in a Private VLAN.A port member of a VLAN can be
isolated to other isolated ports on the same VLAN and Private VLAN.
Web Interface
To configure Port Isolation configuration in the web interface:
1. Click VLAN, Port Isolation.
2. Activate which port want to enable Port Isolation
3. Click Apply.
Figure 3-10.5.1: The Port Isolation Configuration (GS-2310P)
88
LANCOM GS-2310P/GS-2326(P) User Manual
3 Configuration