1AF
3-3-12
(8) Adjustments after installing rollers and solenoids
Perform the following adjustments after detaching and refitting the rollers and solenoids.
(8-1) Adjusting leading edge registration timing
Adjust the registration timing if there is a regular error between the leading edges of the
original and the copy image.
Procedure
Start
Enter simulation mode.
Enter 27 with the numeric keys.
Yes
Yes
No
No
Press the print key.
Press the all clear/reset key.
Press the print key to make a
test copy.
Does the copy image
look like example 1?
Does the copy image
look like example 2?
Increase the setting with the
zoom-up key.
Decrease the setting with the
zoom-down key.
Press the print key.
Setting range: 1 to 100
Reference: 70
Increasing the value makes the secondary
paper feed timing late, and decreasing it makes
the timing early.
The new setting is stored.
Select the mode to be adjusted
with the paper select key.
Mode 1: 100% copy
Mode 2: enlargement copy
Mode 3: reduction copy
Figure 3-3-16
Original
Copy
example 1
Copy
example 2
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...