1AF
3-6-33
(12)
The halogen
lamp does not
light.
(13)
The halogen
lamp does not
turn off.
(14)
The cleaning
lamp does not
light.
(15)
The fixing
heater does
not turn on
(C61, C63).
Broken halogen
lamp filament.
Optical section
thermostat trig-
gered.
Poor contact in the
composite PCB
connector termi-
nals.
Defective main
PCB.
Defective compos-
ite PCB.
Defective main
PCB.
Defective compos-
ite PCB.
Broken cleaning
lamp coil.
Poor contact in the
cleaning lamp con-
nector terminals.
Defective main
PCB.
Broken fixing
heater wire.
Fixing unit thermo-
stat 1 or 2 trig-
gered.
Broken fixing unit
thermistor wire.
Check for continuity. If none, replace the
halogen lamp (see page 3-3-20).
See page 3-6-5.
If HL CONT (PWM) signal is always output
from CN4-5 on the main PCB, replace the
main PCB.
If the halogen lamp does not turn off when
no HL CONT (PWM) signal is input to CN2-7
on the composite PCB, replace the compos-
ite PCB.
Check for continuity. If none, replace the
cleaning lamp.
Check for continuity across the connector
terminals. If none, replace them.
Run simulation 10 and check if CN13-2 on
the main PCB goes low. If not, replace the
main PCB.
Check for continuity. If none, replace the
fixing heater (see page 3-3-57).
Check for continuity across each thermostat.
If none, remove the cause of blowing and
replace the thermostat.
Measure the resistance. If it is
∞ Ω
, replace
the fixing unit thermistor.
Problem
Causes
Check procedures/corrective measures
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...