3-2-8
1AF
Sim.
Description
Remarks
No.
11
Checking switch operation
1. Enter 11 with the numeric keys.
2. Press the print key.
3. Press the all clear/reset key. Test copy mode is
entered.
4. Select the paper source with the paper select key.
5. Press the print key. The copying operation starts
and the paper size indicators turn on and off in se-
quence, showing the status of the individual
switches.
6. Enter 10871087 with the numeric keys. The copier
exits test copy mode and reenters simulation mode.
12
Checking solenoid operation
1. Enter 12 with the numeric keys.
2. Press the print key. The drive motor and developing
bias turn on.
3. Select the solenoid to be operated with the paper
select key.
4. Press the print key. The selected solenoid turns on.
5. Press the stop/clear key. The drive motor and de-
veloping bias turn off.
Check operations
of switches on
the paper con-
veying and opti-
cal systems.
Check solenoid
operation with
the machine
driven.
Mode
Solenoid
1
Bypass solenoid
2
Paper feed solenoid
3
Registration solenoid
Paper size indicator
Switch name
Remarks
A3/11
×
17
Registration switch
A4R/8
1
/
2
×
14
Eject switch
A5R/8
1
/
2
×
11R
Home position switch
A4/5
1
/
2
×
8
1
/
2
R
Lens home position switch
B4/11
×
8
1
/
2
Toner level sensor
Each indicator lights
when the switch it
represents is turned
on.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...