3-2-23
1AF
Sim.
Description
Remarks
No.
73
Checking/clearing service call records
1. Enter 73 with the numeric keys.
2. Press the print key.
•
To check the service call records
3. In mode 1, select the service call record to be
checked by changing the value with the exposure
adjustment keys.
• The larger the value, the older the record.
4. Select mode 2 with paper select key to check the
service call code.
5. Select modes 3, 4 and 5 in order with the paper
select key to check the maintenance count when
the service call code was detected.
•
To clear the service call records
6. Press the all clear/reset key. All the service call
records are cleared.
7. Press the stop/clear key.
Display the
codes and main-
tenance counts
of the last ten
service call de-
tections.
Mode
Copy quantity display
1
Service call detection records (–1 to –10)
2
Service call code
3
Maintenance count, 100,000s and
10,000s digits (0 to 99)
4
Maintenance count, 1,000s and 100s
digits (0 to 99)
5
Maintenance count, 10s and 1s digits
(0 to 99)
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...