1AF
1-3-8
(1-1) Paper feed from the paper drawer
The paper drawer consists of the drawer bottom plate, drawer springs and other components
and can hold up to 250 sheets of copy paper.
Paper is fed out of the drawer by the rotation of paper feed pulleys A and B.
Print key
HPSW
RSW
SM
PFSOL
RSOL
100 ms
147 P+140 ms *
1
Prescan start
250 ms
Timing chart 1-3-1
Paper feed from the paper drawer
A
When the print key is pressed, the paper feed solenoid (PFSOL) turns on for 250 ms,
rotating paper feed pulleys A and B to perform primary feed. Then the paper is fed by
the upper and lower registration rollers and its leading edge stops at the registration
stopper to create slack in the paper before registration.
B
The leading edge of the paper turns the registration switch (RSW) on.
C
The scanner starts scanning and the home position switch (HPSW) turns off. After 147
140 ms, the registration solenoid (RSOL) turns on and the registration stopper
lowers. The lower registration and pre-transfer rollers convey the paper to start
secondary feed.
D
100 ms after the trailing edge has turned the registration switch (RSW) off, the registration
solenoid (RSOL) turns off to complete secondary paper feed.
Auto exposure mode, A4/11"
×
8
1
/
2
" copy paper, magnification ratio 100%
*1 Varies depending on the setting by simulation 27.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...