3-2-15
1AF
Sim.
Description
Remarks
No.
Set the fixing
control tempera-
ture during
standby and
copying.
Mode
Contents
Setting range
Reference
1
Standby (normal temperature
*1
)
170 to 200 (°C)
175°C
2
Standby (low temperature
*2
)
170 to 200 (°C)
177°C
3
During copying (normal tem-
170 to 200 (°C)
175°C
perature)
4
During copying (low tempera-
170 to 200 (°C)
177°C
ture)
5
At the start of copying (normal
170 to 200 (°C)
175°C
temperature)
6
At the start of copying (low
170 to 200 (°C)
182°C
temperature)
Fixing control temperature during
100 to 170 (°C)
100°C
preheat mode
Set the fixing
control tempera-
ture during
preheat mode.
46
Setting the fixing temperature
1. Enter 46 with the numeric keys.
2. Press the print key. The current setting appears on
the copy quantity display.
3. Select a mode with the paper select key.
4. Change the fixing control temperature of the se-
lected mode with the zoom-up/down keys.
*1 Normal temperature: external temperature of 20°C/68°F or above
*2 Low temperature: external temperature below 20°C/68°F
5. Press the print key. The new setting is stored.
6. Press the stop/clear key.
47
Setting the fixing preheat temperature
1. Enter 47 with the numeric keys.
2. Press the print key. The current setting appears on
the copy quantity display.
3. Change the setting with the zoom-up/down keys.
4. Press the print key. The new setting is stored.
5. Press the stop/clear key.
Contents
Setting range
Reference
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...