1AF
3-5-4
Code
Contents
Remarks
Causes
Check procedures/
corrective measures
C40
C50
Lens motor problem
The lens home position
switch does not turn on or
off within 7 s after initial
operation has started.
Shorted high-voltage
transformer PCB
The short problem signal
(HVT ALM) is detected
continuously for 2 s after
the high voltage output
has been turned on.
Defective lens
motor.
Defective lens
home position
switch.
Poor contact
in the lens
home position
switch con-
nector termi-
nals.
Defective
main PCB.
Broken main
charger wire.
The main
charger leaks.
Broken trans-
fer or separa-
tion charger
wire.
The transfer
or separation
charger leaks.
Defective
high-voltage
transformer
PCB.
Defective
main PCB.
Check for continuity across
the coil. If none, replace the
lens motor.
Check if CN5-2 on the main
PCB goes high when the
lens home position switch is
on and goes low when the
switch is off. If not, replace
the lens home position
switch.
Check for continuity across
the connector terminals. If
none, replace them.
Replace the main PCB and
check the operation.
Check the charger wire visu-
ally. If it is broken, replace it.
Check the main charger
housing. If it is dirty, clean it.
Check the charger wires
visually. If either is broken,
replace it.
Check the transfer charger
housing. If it is dirty, clean it.
Detach the main or transfer
charger assembly; if C50
persists, replace the high-
voltage transformer PCB.
Replace the main PCB and
check the operation.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...