1AF
3-6-20
Terminals (CN)
Voltage
Remarks
T1
T2
Local AC supply
AC supply, input
voltage
1-1
1-3
Supply for HL, output
2-1
2-4
24 V DC
24 V DC supply for HVTPCB, output
2-2
2-5
24 V DC
24 V DC supply for MPCB, output
2-3
2-6
5 V DC
5 V DC supply for MPCB, output
2-7
2-5
0/24 V DC (pulse)
HL light intensity control PWM, input
2-8
2-5
0/24 V DC
H on/off, input
2-9
2-5
24 V DC
SSW2 on/off, output
3-1
3-2
5 V DC
5 V DC supply for DM, output
3-4
3-3
24 V DC
24 V DC supply for DM, output
4-1
4-3
Local AC supply
AC supply for H, output
voltage
5-1
2-5
24 V DC
24 V DC supply for SSW2, output
5-3
2-5
0/24 V DC
SSW2 on/off, input
5-5
2-5
0/24 V DC
SSW2 off/on, input
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...