3-2-25
1AF
Sim.
Description
Remarks
No.
76
Checking/clearing the service call counts
1. Enter 76 with the numeric keys.
2. Press the print key. A service call code and its
count appear alternately on the copy quantity dis-
play.
3. Press the paper select key to check the counts of
other service call codes.
•
To clear an individual service call count
4. Select the code to be cleared with the paper select
key and set the value to 0 with the zoom-up/down
keys.
5. Press the print key. The count of the selected code
is cleared.
•
To clear all the service call counts
6. Press the all clear/reset key. All the service call
counts are reset to 0.
7. Press the stop/clear key.
Code
Contents
C20
Drive motor problem
C30
Scanner motor problem
C40
Lens motor problem
C50
Shorted high-voltage transformer PCB
C61
Broken fixing heater filament
C63
Broken fixing unit thermistor wire
C64
Shorted fixing unit thermistor/
abnormally high temperature
C72
Broken drum thermistor wire
C73
Shorted drum thermistor
C74
Broken external temperature
thermistor wire
C75
Shorted external temperature
thermistor
C90
Copier-ADF serial communication
problem
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...