3-2-7
1AF
Sim.
Description
Remarks
No.
4. Press the print key. The new setting is stored.
5. Press the stop/clear key.
06
Checking ADF operation
1. Enter 06 with the numeric keys.
2. Press the print key.
3. Press numeric key 0, 1 or 2 to start ADF operation
check.
4. Press the stop/clear key.
09
Setting shipping defaults
1. Enter 09 with the numeric keys.
2. Press the print key.
3. Press the all clear/reset key. The lens in the lens
unit moves to a position 752 pulses from its home
position and light source unit 1 to a position 3552
pulses from its home position.
4. Turn the main switch off.
10
Turning the drive motor on
1. Enter 10 with the numeric keys.
2. Press the print key. The drive motor and developing
bias turn on, performing toner density control on the
developer.
3. Press the stop/clear key. The operation stops.
Numeric key
Operation
0
Feeding originals continuously
1
Feeding a single original
2
Ejecting originals
Check ADF op-
eration with or
without originals.
To be run before
moving the ma-
chine.
Check the drive
and paper con-
veying system
operations.
05
(cont.)
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...