1AF
3-3-52
(2) Setting transfer voltage (reference)
Perform the following steps after replacing the high-voltage transformer PCB or main PCB,
or if a transfer error occurs at extremely high or low humidity.
Procedure
No
No
Start
Enter simulation mode.
Enter 31 with the numeric keys.
Change the setting with the
zoom-up/down keys.
Press the print key.
The new setting is stored.
Press the stop/clear key.
Exit simulation mode.
End
Yes
Yes
Press the print key.
Is the copy image too light?
Does a transfer error occur?
Setting range: 0 to 7
Reference: 5 (approx. 5.0 kV DC)
Changing the value by one changes
the voltage by 0.1 kV DC (reference).
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...