349
1-1-4
Fixing system ………………… Heat roller
Heat source: halogen heater (850 W with 120 V input,
980 W with 240 V input)
Control temperature: 175°C/347°F (at normal ambient
temperature)
Abnormally high temperature protection devices:
140°C/284°F and 150°C/302°F thermostats
Fixing pressure: 127.4 N
Charge erasing system ……… Exposure by cleaning lamp
Cleaning system ……………… Cleaning blade
Functions ……………………… (1) Self-diagnostics
(2) Simulation
(3) Auto clear (30 – 270 s, in intervals of 30 s)
(4) Auto start
(5) Auto shutoff
(6) Auto preheat/energy saving
(7) Auto exposure
(8) Photo mode
(9) Manual magnification selection
(10) Auto magnification selection (by original size entry)
(11) Auto paper selection (by original size entry)
(12) Auto selection (when the ADF is used)
Power source ………………… 220 – 240 V AC, 50/60 Hz, 6.3 A
120 V AC, 60 Hz, 11.6 A
Rated power consumption …… 1450 W (220 – 240 V AC)
1350 W (120 V AC)
Dimensions …………………… 595 (W)
×
590 (D)
×
375 (H) mm
23
7
/
16
" (W)
×
23
1
/
4
" (D)
×
14
3
/
4
" (H)
Weight ………………………… Approx. 39 kg/66 lbs.
Floor requirements …………… 1120 (W)
×
590 (D) mm
44
1
/
8
" (W)
×
23
1
/
4
" (D)
Accessories …………………… Copy tray
Options ………………………… Key counter, ADF
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...