1AF
1-3-41
Copier’s status
Standby
Start of copying
Copying
Environmental
Low temp.
185°C/356°F
190°C/383°F
185°C/356°F
mode
Normal temp. 175°C/347°F
175°C/347°F
175°C/347°F
• Fixing temperature control in environmental mode
The fixing control temperature is changed as follows during environmental mode or
depending on the status of the copier.
• Environmental mode
1. Low temperature mode: The external temperature is below 20°C/68°F.
2. Normal temperature mode: The external temperature is 20°C/68°F or above.
• Copier’s status
1. Standby
2. Start of copying: from the start of copying to the 10th copy count
3. During copying: 11th copy count and after
Table 1-3-3
Fixing control temperature
• Fixing temperature control in preheat/energy saving mode
During preheat/energy saving mode, the fixing heater (H) is turned on and off to keep the
fixing temperature at 100°C/212°F. Operation after the preheat/energy saving mode is
exited depends on the temperature mode. If the copier is in normal temperature mode,
copying is enabled when the fixing temperature reaches 170°C/338°F without performing
stabilization drive control. In low temperature mode, stabilization drive control takes place
and copying is enabled when the fixing temperature reaches 185°C/356°F. The fixing
control temperature during preheat/energy saving mode can be changed in simulation 47.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...