1AF
1-3-36
Timing chart 1-3-6
Charge erasing
A
When the print key is pressed, the drive motor (DM) and cleaning lamp (CL) turn on to
remove residual charge from the drum surface after residual toner has been removed
in the cleaning section.
B
300 ms after the print key is pressed, all the blank lamps (BL) turn on.
C
75 ms after the scanner has started scanning and the home position switch (HPSW) has
turned off, the required number of blank lamps (BL) for side erasure light depending on
the paper size and the magnification ratio, removing unnecessary charge in the non-
image forming area.
D
1103 ms after the secondary paper feed has started and the registration solenoid
(RSOL) has turned on, all the blank lamps (BL) turn on.
E
1000 ms after the last sheet has been ejected turning the eject switch (ESW) off, the
blank lamps (BL) turn off.
F
1500 ms after the eject switch (ESW) has turned off, the drive motor (DM) and cleaning
lamp (CL) turn off at the same time.
Manual exposure mode, A4/11"
×
8
1
/
2
" copy paper, magnification ratio 100%
*1 Varies depending on the setting by simulation 27.
*2 Varies depending on the magnification ratio and the setting by simulation 54.
*3 Varies depending on the setting by simulation 59.
Print key
HPSW
ESW
SM
DM
RSOL
CL
BL
1500 ms
1000 ms
1103 ms *
3
75 ms *
2
300 ms
Scan start
All on
All on
Side erasure
Secondary paper feed
147 P+140 ms *
1
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...