1AF
3-3-6
(3) Detaching and refitting the bypass upper pulley
Clean or replace the bypass upper pulley as follows.
Procedure
1. Remove the right lower cover.
2. Disengage the stopper hook from the opening in the bypass paper feed shaft by lifting
the shaft slightly, and remove the stopper and bushing from the shaft.
• Do not lift the bypass paper feed shaft too far.
3. Remove the screw and bypass upper pulley from the bypass paper feed shaft.
4. Clean or replace the bypass upper pulley.
5. Refit all the removed parts.
Stopper
Bushing
Bypass upper pulley
Bypass paper feed shaft
Opening
Screw
Hook
Figure 3-3-6
Detaching the bypass upper pulley
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...