background image

ZEUTSCHEL GmbH, Heerweg 2, D-72070 Tübingen-Hirschau, Germany

 

 
 
 

 

 
 
 
 
 

OS 11000 / OK 300 Hybrid Color 

 

 

Installation manual  

 

TS-0412E 19.11.03 

 

Summary of Contents for OK 300 Hybrid Color

Page 1: ...ZEUTSCHEL GmbH Heerweg 2 D 72070 Tübingen Hirschau Germany OS 11000 OK 300 Hybrid Color Installation manual TS 0412E 19 11 03 ...

Page 2: ...rid only 21 2 9 Installing the lamp systems hybrid only 29 2 10 Cable connections for the camera system hybrid only 31 2 11 Cable connections for the scanner system 34 2 12 Installing the air compressor 38 3 Software installation of the OS 11000 OK 300 Hybrid color40 3 1 Required software programs 40 3 2 Installing the Firewire PCI card drivers 40 3 3 Installing the WIDEsystem software 42 3 4 Inst...

Page 3: ...f the OS 11000 OK 300 Hybrid color consists of the following components OT 180 H A0 book cradle 1 Scanner base 2a and scanner unit 2b Microfilm camera 2c with column 2d console 2e lamp system 2f and camera keyboard 2g hybrid only Air compressor 3 Software CDs 4 PCI Firewire host adapter 5 APCI 1500 PC control card ADDI DATA 6 Installation and user manual 7 Basic calibration kit 8 Basic calibration...

Page 4: ...Preparations 4 Fig 2 Fig 3 Fig 4 3 4 5 6 8 7 9 10 11 ...

Page 5: ...e of light Direct sun light has to be avoided A location with indirect illumination is recommended Set up the scanner in a dry and clean environment 1 4 Required tools Hexagon keys Combination wrench 7 12 and 17mm Spirit level Phillips screwdriver Slotted screwdriver Fig 5 ...

Page 6: ...plate should not be removed until the book cradle is installed in the correct position 2 2 Unpacking the scanner Remove first the top cover of the transport container Remove then the beams 12 that keep the scanner unit in transport position Remove the side front and rear covers 13 of the transport container Remove the boxes with the accessories and air compressor Remove the fixing screws and the b...

Page 7: ...Hardware installation 7 Fig 7 Fig 8 14 15 ...

Page 8: ...Hardware installation 8 Fig 9 Fig 10 16 ...

Page 9: ...owing points You need an even floor The room should be as clean as possible avoid dusty or humid environment The scanner should not be installed directly below ceiling lights or close to windows to avoid light reflexes on the glass plate You should install the scanner back side at least 1 5m 5ft away from walls If this is not possible you need at least this space on the front side Put the scanner ...

Page 10: ...Hardware installation 10 Fig 12 Fig 13 19 20 21 45mm ...

Page 11: ...ore lifting Be careful not to damage the glass plate of the book cradle when setting down the scanner base slowly There is less space between the aluminum frame of the base and the glass plate When the scanner base is installed you can move the book cradle backwards until it approaches the fixing brackets 22 which fix the book cradle system at the scanner base on the left and right rear side Remov...

Page 12: ...Hardware installation 12 After the installation the brackets should look like this Fig 16 Fig 17 ...

Page 13: ...t the scanner base During the adjustment of scanner base and book cradle the scanner unit must be moved to the home position which is the outer left position Otherwise the scanner unit could apply pressure to the glass plate and damage it To level the scanner base use a spirit level 24 Put the spirit level on top of the front side guide rail 25 like shown in Fig 18 Now you can adjust the level fro...

Page 14: ...he scanner unit and top of the glass plate Put the spacers first at the left edge 30 of the glass plate one in front and one in rear Then move the scanner unit slowly from the home position towards the glass plate It might be that the scanner unit hits the top of the glass plate when doing this In this case the level of the book cradle has to be lowered by turning the adjustment screws on the supp...

Page 15: ...Hardware installation 15 Fig 20 Fig 21 29 29 30 29 29 ...

Page 16: ... position and check if it does not touch the glass plate in any position Fix the 4 lock nuts Fig 13 21 at the scanner base and the two fixing screws on the book cradle Fig 14 and Fig 15 23 Move the scanner unit manhandled back to the home position to make sure it does not touch anything Remove the spacers from the glass plate 31 ...

Page 17: ...he installation Put the aluminum plate 32 below the column on the floor Install the two fixing pins 33 for the lamp system at the rear of the scanner base like shown in Fig 23 Fig 24 Fig 24 shows the column lying on the floor Remove the fixing screws 34 for the column two on the left and two on the right side Do not yet remove the scotch tape 35 fixing the flat ribbon cables at the column 32 33 33...

Page 18: ...ut in the four dowel pins 35 like shown in Fig 26 ff and drive them in with a hammer These pins are required to bring the column in the correct position against the scanner base For a later removal of the column these pins have a M4 thread inside So a M4 screw can be screwed in to pull the pins out Fig 26 34 34 35 ...

Page 19: ...Hardware installation 19 Fig 27 Fig 28 35 35 ...

Page 20: ...should check if the column is in the upright position see Fig 30 Check the positions front to rear and left to right If the column is not upright you should recheck the leveling of the scanner base As soon as the position is correct you can tighten the 4 fixing screws at the column 35 ...

Page 21: ...camera head and can be driven up and downwards by a motor drive Fig 31 Fig 31 shows the camera head 36 the back cover of the console 37 and the bottom cover of the console 38 Fig 32 Fig 32 shows the console 39 with the air hoses 40 head mounting device 41 and connecting cables 42 The rear axle Fig 33 has been removed for the installation at the column 36 37 38 39 40 41 42 ...

Page 22: ...l the rear axle at the back side of the column and reinstall the two chain locks at the end of the two tension chains One chain is little bit longer than the other this is the safety chain 45 which is normally not under tension In case of a chain break this safety chain will avoid a crash down of the column Fig 34 Fig 34 shows the ready installed rear axle 43 44 45 ...

Page 23: ...console You need the help of a second person Make sure to have the two hexagon fixing screws 46 for the camera console ready Then slide in the console from front to back and install the screws into the threads at both ends of the rear axle When the screws are fixed you can release the console carefully it will move downwards until the first chain is under tension 46 46 ...

Page 24: ...Hardware installation 24 Fig 37 Fig 37 shows the console after installation Fig 38 Now you can install the back cover and the bottom cover at the console ...

Page 25: ... the two 37 pin flat ribbon cables 47 48 at the back side of the console Fig 40 Remove the M3 secure screw 49 and the cable strap 50 at the back side of the chains The chains will be released they are secured during the transport 47 48 50 49 ...

Page 26: ...e camera head The two units are connected by the tension chain and work with the principle of an elevator During transport the counter weight must always be locked with this pint to avoid damages inside the column During operation this pin has to be removed To remove the pin you should release the locking screw at the lock ring 52 and remove the ring Then pull out the lock pin Fig 42 51 52 ...

Page 27: ...e correct position you can fix it with the two secure screws 54 Fig 43 Make the cable connections at the back side of the camera head You have to connect a 37 pin flat ribbon cable 55 a 15 pin flat ribbon cable 56 2 air hoses 57 and a ground connector 58 One of the air hoses is marked with blue marks arrow Do not exchange them One hose is for the vacuum the second one for compressed air Fig 44 53 ...

Page 28: ...n 28 Fig 45 Check now the installation of these connections on the other end at the console Normally these connections are not removed during transport The installation of the camera head console and column is now finished ...

Page 29: ...able during microfilming The lamp systems are packed in separate cartons and have to be assembled before the installation Fig 46 Fig 46 shows the unpacked lamp system Pull out the lamp arm 59 and remove the locking screw 60 Insert the metal pin 61 into the appropriate holes in the lamp arm and reinstall the locking screw Fig 47 59 60 61 ...

Page 30: ... lamp arm stable and to adjust the angle of the lamp system a strut 65 keeps the lamp system in position It has to be fixed at the fixing pins 66 on the back side of the scanner base Remove the locking screw 67 put it through the hole in the strut and install it at the fixing pin like shown in Fig 49 The locking knob 68 on the other end of the strut should be tightened also You will find an adjust...

Page 31: ... control camera control 4 9 pin SubD column camera control 6 25 pin SubD column camera control 7 25 pin SubD book cradle camera control 8 37 pin SubD column camera control 10 9 pin SubD OS 11000 control camera control 16 9 pin AMP left lamp system camera control 17 9 pin AMP right lamp system camera control Ground 71 1 pin flat camera console camera control AC Power 72 3 pin mains socket Mains 230...

Page 32: ...ack side of the pneumatic unit 73 Connection No Connector From To 18 25 pin SubD column pneumatic unit 19 1 air socket console air hose pneumatic unit 20 1 air socket console air hose pneumatic unit 21 1 air socket air compressor air hose pneumatic unit Fig 51 73 ...

Page 33: ...oard keyboard 75 15 pin Sub D OS 11000 control unit camera keyboard trigger cam 76 6 pin round OS 11000 control unit camera keyboard Fig 52 Connection Connector From To keyboard 77 15 pin Sub D OS 11000 control unit camera keyboard trigger cam 78 6 pin round OS 11000 control unit camera keyboard foot pedal 79 5 pin round camera foot pedal camera keyboard Fig 53 76 75 74 78 77 79 74 ...

Page 34: ...und OS 11000 control unit scanner unit Firewire 82 6 pin Firewire scanner PC scanner unit AC Power 83 3 pin power socket OS 11000 control unit scanner unit Fig 54 Switch on the power switch 84 This switch can normally stay in on position except for service purposes The scanner PC should have at least the following configuration CPU Interface Connector Memory RAM Video Card Min Resolution Pentium I...

Page 35: ...for the PC control 85 and Firewire interface 86 in an unused PCI slot Close the PC and make the following connections Fig 56 Connection Connector From To Firewire 4m 87 6 pin Firewire scanner unit scanner PC PC control 1 5m 88 37 pin subD OS 11000 control unit scanner PC 85 86 87 88 ...

Page 36: ...tallation 36 Fig 57 If necessary the Firewire cable can be elongated by using a gender changer 89 and an additional Firewire cable up to 2m Fig 58 The PC control cable 90 is connected at the OS 11000 control 89 90 ...

Page 37: ... is equipped with two plugs The cable goes from the book cradle to the camera control unit Fig 50 and then to the OS 11000 control Fig 59 Connect the power cables at the scanner unit Connection Connector From To AC Power in 92 3 pin power socket OS 11000 control unit mains input Fig 61 99 AC scanner power 93 3 pin power socket OS 11000 control unit scanner unit AC book cradle power 94 3 pin power ...

Page 38: ...e camera control unit at the back side of the scanner base Fig 61 Check the oil level at both cylinders Fig 62 95 It should be between MIN and MAX margin If the level is below the MIN level refill compressor oil Do not fill above MAX level Read the air compressor user manual for installation and maintenance Fig 62 95 98 99 ...

Page 39: ...r cable of the compressor 98 to the multi plug power socket 99 delivered with the OS 11000 Turn the power switch 100 into the 1 position the compressor will start pumping air into the air tank After a few minutes the air tank should be filled with air Adjust now the pressure level of the compressor at the regulator valve 101 to 5 5 bars If there is no pressure check if the air valve 102 is open Yo...

Page 40: ...of the scanner unit on the table 3 2 Installing the Firewire PCI card drivers The OS11000 is delivered with a Firewire data interface which transfers the image data from the scanner to the PC The required Firewire PCI card is delivered with the scanner and should be installed in your PC With the next system boot up the new hardware will be automatically detected by your plug play operating system ...

Page 41: ...Software installation 41 The driver properties should look like this or similar depending on your Windows version Fig 66 ...

Page 42: ...ool you will detect a small scanner icon 101 in your systray on the right bottom of your task bar You can double click any time on the scanner symbol to open the status monitor Clicking on the X will minimize the status window back to the systray but not terminate the application Fig 67 In addition the scanner software drivers will be installed on your Windows system otherwise the connected scanne...

Page 43: ...tallation 43 To install WIDEsystem on your PC follow these steps 1 Insert WIDEsystem CD ROM into your CD ROM drive and open the root directory Fig 68 2 Execute the file Setup exe the installation will start Fig 69 ...

Page 44: ...Software installation 44 3 Select the desired installation language Fig 70 4 Click on Install WIDEsystem Software the installation procedure will copy the required files to your PC Fig 71 ...

Page 45: ...Software installation 45 Fig 72 5 The program will ask whether the WIDEsystem tool should be run at the startup of Windows confirm with YES Fig 73 ...

Page 46: ... to your PC and the scanner is switched on Then confirm with YES Fig 74 7 The PC will reboot after the restart of Windows a new hardware device Cougar 36 Tx 1394 1 will be detected Fig 75 8 Click on YES to go on with the installation procedure 1 Cougar 36 Tx is the product name of the OS11000 scanner engine manufactured by Contex ...

Page 47: ...ation 47 9 Open your device manager and check the correct installation of the scanner device 102 Fig 76 10 Double click on the scanner device and verify if the scanner is operational then click on driver tab Fig 77 102 ...

Page 48: ...n 48 11 Verify if the file scsiscan sys is installed in your System32 drivers directory then close the device manager Fig 78 12 Double click on the WIDEsystem icon in the systray you should get the following screen Fig 79 ...

Page 49: ...mage data from the scanner unit displays it on the PC screen allows you image modifications and finally stores the image on your harddisk or network To install WIDEimage on your PC follow these steps 1 Insert WIDEimage CD ROM into your CD ROM drive and open the root directory Fig 80 2 Execute the file Setup exe the installation will start Fig 81 ...

Page 50: ...ng the installation you will be prompted for a serial number to license your software You ll find this S N on the back side of the CD Cover of your WIDEimage CD ROM Enter the S N and your Name Company then the installation will start Fig 83 ...

Page 51: ...Software installation 51 Fig 84 4 Click on Finish to complete the installation Fig 85 ...

Page 52: ...he movements and status of the scanner unit This card is named ADDI Data APCI1500 and is provided together with the scanner Install the card like described in the chapter above To install the ADDI Data drivers on your PC follow these steps 1 Insert the ADDI Data CD ROM 1 into your CD ROM drive and open the root directory Fig 86 2 Open the folder APCI1500 Fig 87 ...

Page 53: ...Software installation 53 3 Open the folder Win XP 2000 NT 98 Fig 88 4 Open the folder driver Fig 89 5 Open the folder Disk1 Fig 90 ...

Page 54: ...Software installation 54 6 Execute the file Setup exe Fig 91 7 Click on Next Fig 92 8 Click on Yes Fig 93 ...

Page 55: ...e and Company Name Fig 94 10 Click on Finish Fig 95 The installation of the drivers is finished IMPORTANT To make the card operate a registration in the PC system is required You must also install the tool ADDI Reg which is available on the CD ROM ...

Page 56: ...Software installation 56 11 Open the folder ADDIREG in the root directory of your ADDI Data installation CD ROM Fig 96 12 Execute the file Setup exe Fig 97 13 Select your installation language Fig 98 ...

Page 57: ...Software installation 57 14 Click on Next Fig 99 15 Click on Yes Fig 100 16 Enter your User and Company name Fig 101 ...

Page 58: ...Software installation 58 17 Select a program folder for the installation Fig 102 18 Click on Finish Fig 103 19 Click on Start Programs Zeutschel AddiReg Fig 104 ...

Page 59: ...Software installation 59 20 An empty list of PCI boards will appear Fig 105 21 Click on Insert and select the board type APCI1500 from the scroll list then click OK Fig 106 ...

Page 60: ...Software installation 60 22 The APCI1500 board will appear and the board configuration parameters will be displayed Click then on Save Fig 107 23 Click on the button Test registration Fig 108 ...

Page 61: ...Software installation 61 24 If the following message appears the board registration was successful You can finish the ADDI REG program by pressing Quit Fig 109 ...

Page 62: ...etc The control program will automatically handle some security functions like locking of the glass plate camera head hybrid only etc To install the control program on your PC follow these steps 1 Insert the OS11000 installation CD ROM into your CD ROM drive and open the root directory Fig 110 2 Copy the files from the sub folder Control program to your harddisk i e in a folder C Programs Zeutsche...

Page 63: ...y them to a the autostart folder of All users b the PC desktop Copying the shortcuts to the autostart folder starts the required programs automatically as soon as the user logs on to his Windows computer The scanner is ready for operation The icons on the desktop help the user to restart manually the programs if required HINT The WIDEsystem shortcut is automatically created with the installation o...

Page 64: ... Data control card is correctly installed you will get the following window Fig 113 Check for the message 1 board s found Then click on the START button the control panel is ready for operation In case of an error message check again the correct installation of the control card by using the ADDIReg program ...

Page 65: ...ns format size color depth resolution speed aperture etc i e A1_24Bit_200dpi_Average4_Aperture8 jpg Description of the used PC Type z B i e DELL Pentium4 2 2 GHz 1 GB DDR RAM RAID Controller etc Description of the used operating system with Service Pack No and language i e Win 2000 SP2 English Description of the used scan software version with built date i e OMNISCAN 10 x from 29th April 2003 see ...

Page 66: ...cturer 66 5 Manufacturer ZEUTSCHEL GMBH Heerweg 2 D 72070 Tübingen Germany Tel 49 0 7071 9706 0 Fax 49 0 7071 9706 44 email info zeutschel de Internet www zeutschel de Technical equipment is subject to change ...

Page 67: ... system Scanner unit Scanner base Book cradle Air compressor Scanner unit power 3 Book cradle power 3 PC Control 37 Firewire 6 PCI Firewire card PCI control card Automatic cable 25 AC Power in 230V 50 60 Hz Scanner control Air hose 1 Control 2 15 Control 1 15 Scanner power 3 PC power 3 Compressor power 3 Zahlen in Klammern z B 3 bezeichnen die Anzahl d Pins am Stecker Numbers in brackets i e 3 dec...

Page 68: ...ruckluftschlauch Air hose Zahlen in Klammern z B 3 bezeichnen die Anzahl d Pins am Stecker Numbers in brackets i e 3 declare the number of pins at the connector Control 1 15 Control 2 15 Scanner unit power 3 Firewire 6 Camera power 3 17 16 Air hose 1 Power right lamp 3 Spiral air hose 2 Camera Head Console Console cable 1 37 Console cable 2 37 Air hose 1 Air hose 1 Ground cable 1 Projection lamp 1...

Reviews: