3-6-15
1AF
(20) Image is not square
laterally.
Causes
1. The height of the mirrors 4 & 5 frame is adjusted
incorrectly.
1. The height of the
mirrors 4 & 5 frame is
adjusted incorrectly.
Adjust the lateral squareness of the image (see page
3-3-27).
Causes
Check procedures/corrective measures
(21) Image is partially
missing laterally.
Causes
1. Registration solenoid incorrectly installed or
malfunctioning.
2. Paper feed solenoid incorrectly installed or
malfunctioning.
1. Registration solenoid
incorrectly installed or
malfunctioning.
2. Paper feed solenoid
incorrectly installed or
malfunctioning.
Check and correct the solenoid installation position and its
operation.
Check and correct the solenoid installation alignment and
its operation.
Causes
Check procedures/corrective measures
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...