1AF
1-3-29
• Correction based on the drive time
The toner sensor control voltage (TNS CONT) is decreased as the developing unit drive
time [the total time the drive motor (DM) has been on] increases from execution of simulation
60.
0
0.19
–0.29
–0.50
Drive time (h)
0
0.5
4
2
15
40
60
100
Drive time correction value (V)
Figure 1-3-27
Correction based on the drive time