1AF
3-3-34
(9) Adjusting the auto exposure (AE sensor) reference value
Procedure
Enter simulation mode.
Enter 22 with the numeric keys.
Start
End
Press the print key.
Select mode 2 with the paper
select key.
Check that exposure is correctly
set in (8) Setting the exposure
amount.
Place ten sheets of A3/11"
×
17"
plain white paper on the contact
glass.
Press the all clear/reset key (to
prescan repeatedly).
Press the all clear/reset key (to
start prescanning).
Place the NTC on the contact
glass.
Select mode 3 with the paper
select key.
Press the all clear/reset key
(to start prescanning).
Place the NPTC on the contact
glass.
Press the stop/clear key.
Exit simulation mode.
Select mode 1 with the paper
select key.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...