Setting the drum potential
1. Enter 32 with the numeric keys.
2. Press the print key.
3. Select a mode with the paper select key.
4. Change the setting with the zoom-up/down keys.
5. Press the print key. The new setting is stored.
6. Press the all clear/reset key. Operation check mode
is entered and the following operation takes place
under the new setting.
Timing chart 3-2-2
7. Press the all clear/reset key. The operation stops.
8. Press the stop/clear key.
200 ms
200 ms
All clear/reset key
DM
Dev. Bias
MC
SC
1200 ms
1000 ms
2932 ms
2675 ms
Mode
Contents
Setting range
Reference
1
Normal-mode grid control value
0 to 255
190
2
Normal-mode main charging
0 to 3
1
control value
3
Photo-mode grid control value
0 to 255
100
4
Photo-mode main charging
0 to 3
1
control value
See page 3-3-44.
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...