1AF
3-3-9
(5) Adjusting the position of the original size indicator
Perform the following adjustment if there is a regular error between the centers of the original
and the copy image.
Procedure
Yes
No
Start
Make a test copy at 100% with
the maximum size of copy paper.
Is the center of the
image aligned with
that of the original?
End
Screw
Original size indicator
Figure 3-3-11
Adjusting the position of the original size indicator
Original
Copy
example 1
Copy
example 2
Figure 3-3-10