1AF
3-6-34
(16)
The fixing
heater does
not turn off
(fixing unit
thermostat 1
or 2 triggered,
C64).
(17)
Main charging
does not take
place.
(18)
Transfer
charging does
not take
place.
Dirty sensor part of
the fixing unit ther-
mistor.
Defective compos-
ite PCB.
Defective main
PCB.
Broken main
charger wire.
Leaking main
charger housing.
Poor contact in the
high-voltage trans-
former PCB con-
nector terminals.
Defective main
PCB.
Defective high-
voltage trans-
former PCB.
Broken transfer
charger wire.
Leaking transfer
charger housing.
Poor contact in the
high-voltage trans-
former PCB con-
nector terminals.
Defective main
PCB.
Defective high-
voltage trans-
former PCB.
Check visually and clean the thermistor sen-
sor parts.
If the fixing heater stays on with CN2-8 on
the composite PCB high, replace the com-
posite PCB.
If CN4-6 on the main PCB is always low,
replace the main PCB.
Check visually and replace the main charger
wire if it is broken (see page 3-3-17).
See page 3-6-4.
Check visually and replace the transfer
charger wire if it is broken (see page
3-3-49).
See page 3-6-4.
Problem
Causes
Check procedures/corrective measures
Summary of Contents for DC-1560
Page 1: ...DC 1560 2050 KME S M SERVICE MANUAL Published in Oct 99 841AF110 DC 1560 2050 DC 1560 2050...
Page 3: ...SERVICE MANUAL DC 1560 2050...
Page 13: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 15: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 27: ...DC 1560 2050 KME S M I Theory and Construction Section THEORY AND CONSTRUCTION SECTION I...
Page 33: ...1 1 7 1AF CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Page 78: ...DC 1560 2050 KME S M ELECTRICAL SECTION II II Electrical Section...
Page 79: ...1 1 11 1AF CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 98: ...DC 1560 2050 KME S M III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 169: ...1AF 3 3 13 End Yes No Press the stop clear key Exit simulation mode Adjust for another mode...
Page 201: ...1AF 3 3 45 End Yes Press the stop clear key Exit simulation mode No Adjust for another mode...