SF05 Monitored stop
What does SF05 monitor?
, monitors the velocity of each joint and makes sure the velocity is zero
when the robot is not moving. It makes sure the arm remains in a standstill position.
Cause of the trigger
Motion in the
is detected and results in a stop category 0. For example, the robot stops
moving when it is vibrating a lot.
Remedy
1.
Remove the external source of motion.
2.
Add damping elements to each source of vibration that is in contact with the robot.
Related topics
on page 52
SF06 Protection zone monitoring
What does SF06 monitor?
SF06 monitors the robot to make sure no part of the robot, including the user-defined tool sphere,
comes in contact with any of the user-defined
protection zones
that are enabled.
Cause of the trigger
The robot touches an enabled protection zone when operating in Manual or running a program. It
Remedy
1.
Power the robot.
2.
Clear the fault.
3.
Use Recovery mode to leave the protection zone.
4.
Reconfigure protection zones if necessary and safe from
Safety
>
Protection Zones
in
5.
Disable protection zones if necessary and safe from
Safety
>
Protection Zones
in
Kortex Web App.
Related topics
on page 99
on page 69