EN UG-020 Link 6 user guide r1.0
117
Installing the controller on a flat surface
must never be in a position where it can slip or fall.
Before you begin
Personnel
•
Number of Workers:
1
Supplies
• 4 x M6-1.0-6h screws, closed end nut inserts
Note:
Maximum thread engagement depth: 6 mm
Note:
Torque: 7-9 N·m
Figure 97: Mounting points of the controller, measured in millimeters
About this task
Verify the technical specifications of the controller to ensure there is maximum airflow around
the controller, as well as enough space to hold the controller without putting it in a position in
which it can be bumped.
The controller does come with anti-slip feet. Therefore, it is possible that placing it on a suitable
flat surface suffices.
Alternatively, the controller can be secured to a flat surface.
Procedure
1.
Align the foot mounts on the controller with the holes in the stable surface.
2.
Place each of the M6 screws from under the surface into the foot mount location on the
controller.