EN UG-020 Link 6 user guide r1.0
116
Figure 95: Linear perspective of the controller
and its airflow requirements
Figure 96: Top view of the controller and its
airflow requirements
1
Minimum 50 cm from the wall for fan airflow
2
Minimum 10 cm from the wall
3
Easy access to connectors, switches, and LED status
4
Easy access to I/O panel
If there is no access to the underside of the installation surface and there is no need to fix it,
leave the controller on its four rubber feet. However, if there is a need to fix it and it cannot be
fixed to the installation surface, use the optional Kinova wall bracket.
The controller must be kept within specific temperatures ranges during storage and use.
Table 65: Safe temperatures for the controller
Action
Minimum temperature
Maximum temperature
Storage
-40 °C
65 °C
Powering up
0 °C
40 °C
Operating
-20 °C
40 °C