EN UG-020 Link 6 user guide r1.0
63
Equally important in knowing the timeline of a safety function is knowing where to find the
current safety function status. For the status of SF05 Monitored stop0 function, there is one
place to look in Kortex Web App:
Diagnostics
>
Status
>
Safety Functions
.
Table 43: SF05 trigger and action timeline
Monitor frequency of trigger
0.01 s
Trigger
• The arm is in the process of stopping and has taken more
than 1000 ms to stop.
• The difference between the actual position of at least one
joint and its position when the robot entered the stop state
is more than 0.5°.
Trigger results
• Stop category 0 is deployed.
• The arm is in the state Fault power off.
Reset
Tap
CLEAR FAULT
.
Reset result
The operating mode is Monitored Stop.
Failsafe
When SF05 does not receive joint positions for more than 60 ms, stop
category 0 is deployed.
Brake
Release
Idle
Initialization
Maintenance
Fault
power on
SF05
active
SF05
inactive
Arm:
Operating modes:
Operational
Recovery
Figure 46: Timeline for SF05 before and after being triggered
SF06 Protection zone monitoring timeline
Each safety function enters one of two states during operations; it depends on the current state
of the arm and the current mode of operation.