EN UG-020 Link 6 user guide r1.0
62
Table 42: SF04 trigger and action timeline
Monitor frequency of trigger
0.01 s
Trigger
The speed of at least one joint is faster than the configured limit.
Trigger results
• Stop category 2 is deployed.
• The operating mode is Monitored Stop.
• The arm is in the state Fault power on.
Reset conditions
The speed of the joints are corrected to be within operational limits.
Reset
Tap
CLEAR FAULT
.
Reset result
Normal conditions lead to two results.
• The operating mode is Monitored Stop.
• The arm does not move.
Failsafe
SF04 can experience processing errors. In this case, stop category 0
is deployed.
SF04
active
SF04
inactive
Brake
Release
Arm:
Idle
Initialization
Maintenance
Fault
power on
Operating modes:
Operational
Recovery
Figure 45: Timeline for SF04 before and after being triggered
Related topics
State timeline for the safety output Normal Speed Mode
SF05 Monitored stop timeline
Each safety function enters one of two states during operations; it depends on the current state
of the arm and the current mode of operation.