Cause of the trigger #2
The robot is not calibrated.
Remedy for trigger #2
Procedure
1.
Tap
Systems
>
Robot
>
Arm
.
2.
Expand the
Calibration
pane.
3.
Verify that the calibration status is
Not Calibrated
.
4.
Tap
Import
in the
Import calibration file
panel to upload the calibration file to the robot.
Important:
Contact [email protected] if the administrator does not have a backup of
the calibration file.
5.
Verify that the calibration status is
Calibrated
Related topics
on page 152
on page 151
Configuring the arm for robot controls
on page 156
Why is the computer not connecting to Kortex Web App?
Condition
The controller is on, but
is not displayed on the computer.
Cause #1
The Ethernet cable is not connected to the computer or the controller.
Remedy #1
Make sure one end of the Ethernet cable is connected to the controller and that the other end is
connected to the computer.
Cause #2
The netmask of the Ethernet interface on the computer does not match the IP address of the
controller.
Remedy #2
Make sure the netmask of your Ethernet interface is appropriate for the range of the two or
more devices that are communicating with the robot. The default IP address of the controller is
192.168.1.10
.
Cause #3
A user is logged on with the teach pendant.
Remedy #3
Make the user who is using the teach pendant log out.