EN UG-020 Link 6 user guide r1.0
44
Connector A
Connector B
Pin #
Label
Purpose
Label
Purpose
5
+24v
Power
+24v
Power
6
DIGITAL_IO3
Digital In/Out
DIGITIAL_IO7 Digital In/Out
7
DIGITAL_IO4
Digital In/Out
DIGITIAL_IO8 Digital In/Out
8
GND
Ground
GND
Ground
Wrist power supply
The maximum current is shared among all power outputs of the wrist, including the A and B
connectors and the pogo pad.
The wrist can handle a maximum of 5 A among all connection points. If one M8 connector is
using 1 A, there is only 4 A left for the other interfaces.
Important:
The maximum current that can be used by any one M8 connector is 1.4 A.
General-purpose inputs and outputs for the wrist
Unless otherwise specified, all general-purpose digital and analog inputs and outputs have the
same specifications as the
Related topics
General-purpose digital inputs
on page 35
General-purpose digital outputs
on page 36
on page 38
on page 38
Wrist RS-485
on the wrist is used only for Modbus
when it is exposed through EIA/TIA-485-A,
commonly referred to as RS-485.
Important:
There is no
communication available from
.
Table 33: RS-485 pins on the wrist
Label
Purpose
RS_485_P
RS-485 D+ (B)
RS_485_N
RS-485 D- (A)
GND
RS-485 SC (G)
Table 34: RS-485 power inputs
RS-485
Min
Typical
Max
Unit
Input voltage at A/B terminal
-7
5
12
V
Current
2
A
+1 514-277-3777
kinovarobotics.com
© 2022 Kinova inc. All rights reserved.