EN UG-020 Link 6 user guide r1.0
259
Installing the external 3-position enabling device
Whenever you need to install an external 3-position
, be sure to read and follow all
mounting instructions from the manufacturer.
Before you begin
Personnel:
•
Number of Workers:
1
Supplies
• 1 x 3-position enabling device
• 1 x Cable
Tools
• Ferrule (optional)
About this task
View or download publications at
.
Procedure
1.
Make sure the
is switched off.
2.
Follow the wiring instructions in Industrial I/O Safety I/O inputs.
Wiring for use of Channel 0
Terminal (Controller side)
Wire color
Pin (Device side)
AI_0
Black
2
24_o (Bank A)
Red
1
BI_0
White
4
24_o (Bank B)
Yellow
3
3.
Set the Safety I/O to
Enabling Device
.
Related topics
on page 78
+1 514-277-3777
kinovarobotics.com