EN UG-020 Link 6 user guide r1.0
33
The general-purpose
I/O
s are powered by 24 V IN or 0 V IN terminals. The terminals can receive
their power from 24 V OUT or 0 V OUT terminals, or from an external power supply. The general-
purpose I/Os contains eight (8) digital inputs, eight (8) digital outputs, four (4) analog I/Os, and
provisions for high-speed encoder inputs.
The
is designed to comply with specific standards.
• Immunity requirements for safety I/O are designed for accordance with IEC 61000-6-7.
• Safety digital inputs and general-purpose digital inputs are designed for accordance with IEC
61131-2 Type 1 and Type 3.
• Safety digital outputs and general-purpose digital outputs are designed for accordance with
IEC 61131-2 Type 1 and Type 3.
•
electrostatic discharge (ESD)
, surge, and
Electrical Fast Transient(EFT)
are designed for
accordance with IEC 62326-3-1.
Positive logic, which is current sinking input and current sourcing output, is supported on the
panel.
Negative logic (NPN)
is not supported on the panel.
Figure 29: Default factory setting with internal supply used and external E-stop bypassed
Table 15: Industrial I/O terminals
Mechanical
Min
Typical
Max
Unit
Conductor size (
16
24
American Wire
Gauge (AWG)
Conductor size (
International
Electrotechnical Commission
(IEC)
)
0.2
1.5
mm
2
Stripping Length
8
10
mm
Terminal pitch
3.5
mm
Ferrule
Deutsches Institut
für Normung (DIN)
46228-4
Related topics