EN UG-020 Link 6 user guide r1.0
85
Trigger off
The robot must be in one of the arm states to exit the Arm Moving
state.
• Initialization
• Idle
• Maintenance
• Brake Release
• Fault power off
• Fault power on
Alternatively, the robot must be in the operating mode Monitored
Stop.
Trigger on
The arm must be operational and the robot must be in one of the
operating modes to enter the Arm Moving state.
• Automatic
• Hand Guiding
• Hold-to-Run
• Manual Jog
Brake
Release
Idle
Initialization
Fault
Arm:
Operating modes:
Operational
Maintenance
Monitored Stop
Figure 68: Timeline for the safety output Arm Moving
State timeline for the safety output Normal Speed Mode
Each safety output enters one of two states during operations.
Safety Mode
is defined as either
Normal
speed or
Reduced
speed. To know the status of the
Normal Speed Mode
, look at the
Safety Mode
drop-down in different areas of Kortex Web App.
•
Safety
>
Joint Limits
>
Speed Limits
•
Safety
>
TCP & Elbow Limits
>
TCP Limits
•
Safety
>
TCP & Elbow Limits
>
Elbow Limits
•
Programs
>
<select a program>
: the Program speed control area of the Robot control panel
Table 59: Normal Speed Mode timeline
Delay of trigger
0.02 s
Trigger off
•
Reduced
is selected from the
Safety Mode
drop-down or in
the Program speed control of the Robot control panel.
• The safety system is set to
Reduced
.
+1 514-277-3777