EN UG-020 Link 6 user guide r1.0
36
Table 19: Digital inputs
Digital inputs
Min
Typical
Max
Unit
Note
Low state voltage
-3
0
5
V DC
High state voltage
11
24
30
V DC
Current
2.0
2.6
mA
Voltage drop
Function
Current sinking
IEC 61131-2 Type
1, 3
Digital input type 1 and 3 designed
for accordance with IEC 61131-2
Each wetting port is designed to provide the power needed for a single input point. Do not use it
as a generic power source.
The terminal connections belong to the GENERAL PURPOSE terminal group.
Table 20: Digital input terminal connections
Label
Purpose
DI_n (n=[0-7]
Terminal points for digital input
24_o
Wetting port for each digital input
Each input has its own wetting port.
Figure 32: Digital input terminal connections
General-purpose digital outputs
All 0 V ports are common, although each output has its own 0 V terminal.
All the digital outputs are short-circuit protected. An incorrect terminal connection does not lead
to any permanent damage.
There are isolation potentials between a channel and other circuits, including earth, as well as
between channels under normal operation.