Power Meter Remote Operation
1
Keysight N8262A Programming Guide
69
The following examples use the source list parameter to specify the measurement
channel as Channel A. The expected power and resolution parameters are
defaulted, leaving them at their current settings. The measurement is carried out
on the upper window.
Although the
READ?
and
FETCh?
queries have three optional parameters it is not
necessary to define them as shown in these examples. If they are defined they
must be identical to those defined in the
CONFigure
command otherwise an error
occurs.
Using READ?
Using INITiate and FETCh?
Example 3 - Specifying the Expected Power Parameter
The previous example details the three optional parameters which can be used
with the
CONFigure
and
READ?
commands. The first optional parameter is used to
enter an expected power value. Entering this parameter is only relevant if you are
using an E-Series power sensor. The value entered determines which of the power
sensor’s two ranges is used for the measurement. If the current setting of the
power sensor’s range is no longer valid for the new measurement, specifying the
expected power value decreases the time taken to obtain a result.
ABOR1
Aborts Channel A
CONF1 DEF,DEF,(@1)
Configures the upper window to make a
Channel A measurement using the current
expected power and resolution settings
READ1?
Takes the upper window’s measurement
ABOR1
Aborts Channel A
CONF1 DEF,DEF,(@1)
Configures the upper window to make a
Channel A measurement using the current
expected power and resolution settings
INIT1
Causes Channel A to make a measurement
FETC1? DEF,DEF,(@1)
Retrieves the upper window’s measurement
Summary of Contents for N8262A
Page 1: ...Keysight N8262A P Series Modular Power Meter Programming Guide ...
Page 6: ...6 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 48: ...48 Keysight N8262A Programming Guide ...
Page 50: ...50 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 54: ...54 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 648: ...16 SERVice Subsystem 648 Keysight N8262A Programming Guide ...
Page 649: ...SERVice Subsystem 16 Keysight N8262A Programming Guide 649 ...
Page 668: ...17 IEEE 488 2 Command Reference 668 Keysight N8262A Programming Guide Syntax STB ...