CONFigure[1]|2|3|4[:SCALar][:POWer:AC]:RATio:
RELative[<expected_value>[,<resolution>[,<source list>]]]
This command sets the measurement function, range and resolution of the
specified window. It sets the measurement function to ratio with relative mode on.
The relative value used is that set by the
CALCulate:RELative:MAGNitude:AUTO
command.
Syntax
Parameters
on page 126 for additional details on the
parameters in this command.
:POW
:AC
:SCAL
:RAT
:REL
Space
expected_value
DEF
resolution
,
DEF
source list
,
CONF
1
2
3
4
Item
Description/Default
Range of Values
expected_value
(for the expected power level)
The power meter ignores the numeric value entered in
this parameter. Any value entered is treated like
DEF
.
Sensor dependent
DEF
[a]
resolution
A numeric value for the resolution. If unspecified the
current resolution setting is used.
1 to 4
[b]
1.0, 0.1, 0.01, 0.001
DEF
source list
This channel list specifies the channels used to
calculate the ratio.
If unspecified and the current window setup is a ratio
measurement then this ratio setup is used, otherwise it
defaults to Channel A/B.
(@1),(@2)
(@2),(@1)
(@1),(@1)
(@2),(@2)
Summary of Contents for N8262A
Page 1: ...Keysight N8262A P Series Modular Power Meter Programming Guide ...
Page 6: ...6 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 48: ...48 Keysight N8262A Programming Guide ...
Page 50: ...50 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 54: ...54 Keysight N8262A Programming Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 648: ...16 SERVice Subsystem 648 Keysight N8262A Programming Guide ...
Page 649: ...SERVice Subsystem 16 Keysight N8262A Programming Guide 649 ...
Page 668: ...17 IEEE 488 2 Command Reference 668 Keysight N8262A Programming Guide Syntax STB ...