AT-194
[RE4F04B]
DTC BATT/FLUID TEMP SEN (A/T FLUID TEMP SENSOR CIRCUIT AND TCM
POWER SOURCE)
Revision: November 2006
2006 Altima
DTC BATT/FLUID TEMP SEN (A/T FLUID TEMP SENSOR CIRCUIT AND TCM
POWER SOURCE)
PFP:31940
Description
ECS00996
The A/T fluid temperature sensor detects the A/T fluid temperature
and sends a signal to the TCM.
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
Remarks: Specification data are reference values.
On Board Diagnosis Logic
ECS00997
Diagnostic trouble code BATT/FLUID TEMP SEN with CONSULT-II or 8th judgement flicker without CON-
SULT-II is detected when TCM receives an excessively low or high voltage from the sensor.
Possible Cause
ECS00998
Check the following items.
●
Harness or connectors
(The sensor circuit is open or shorted.)
●
A/T fluid temperature sensor
Diagnostic Trouble Code (DTC) Confirmation Procedure
ECS00999
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-II
1.
Start engine.
SAT283HB
SAT021J
Monitor item
Condition
Specification (Approximately)
A/T fluid temperature sensor
Cold [20
°
C (68
°
F)]
↓
Hot [80
°
C (176
°
F)]
1.5V
↓
0.5V
2.5 k
Ω
↓
0.3 k
Ω