TROUBLE DIAGNOSIS FOR SYMPTOMS
AT-611
[RE5F22A]
D
E
F
G
H
I
J
K
L
M
A
B
AT
Revision: November 2006
2006 Altima
DIAGNOSTIC PROCEDURE
1.
CHECK A/T FLUID LEVEL
Check the A/T fluid level. Refer to
OK or NG
OK
>> GO TO 2.
NG
>> Refill ATF.
2.
CHECK STOP LAMP SWITCH CIRCUIT
Check the stop lamp switch circuit. Refer to
(with ABS),
(with TCS/ABS).
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace damaged parts.
3.
CHECK SELF-DIAGNOSTIC RESULTS
Perform self-diagnosis.
Is any malfunction detected by self-diagnostic?
YES
>> Check the malfunctioning system.
NO
>> GO TO 4.
4.
DETECT MALFUNCTIONING ITEM
1.
Control valve assembly. Refer to
AT-629, "Control Valve Assembly"
2.
Disassemble A/T. Refer to
3.
Check the following items:
–
Torque converter. Refer to
OK or NG
OK
>> GO TO 5.
NG
>> Repair or replace damaged parts.
5.
CHECK TCM
1.
Check TCM input/output signal. Refer to
AT-459, "TCM Input/Output Signal Reference Values"
2.
If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK
>> GO TO 6.
NG
>> Repair or replace damaged parts.
6.
CHECK SYMPTOM
Check again.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace damaged parts.
Lock-up Is Not Released
ECS009IU
SYMPTOM:
The lock-up condition cannot be cancelled even after releasing the accelerator pedal.