DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
AT-487
[RE5F22A]
D
E
F
G
H
I
J
K
L
M
A
B
AT
Revision: November 2006
2006 Altima
5.
CHECK A/T FLUID TEMPERATURE SENSOR
1.
2.
Disconnect A/T fluid temperature sensor.
3.
Check resistance between terminals 4 and 8.
OK or NG
OK
>> GO TO 6.
NG
>> Repair or replace terminal cord assembly. Refer to
.
6.
CHECK DTC
Perform “DTC Confirmation Procedure”. Refer to
AT-483, "DTC Confirmation Procedure"
OK or NG
OK
>> INSPECTION END
NG
>> GO TO 7.
7.
CHECK TCM
1.
Check TCM input/output signal. Refer to
AT-459, "TCM Input/Output Signal Reference Values"
2.
If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace damaged parts.
Component Inspection
ECS009E4
A/T FLUID TEMPERATURE SENSOR
1.
2.
Disconnect A/T fluid temperature sensor.
3.
Check resistance between terminals 4 and 8.
4.
If NG, repair and replace terminal cord assembly. Refer to
.
Connector
Terminal
Temperature
Resistance
F30
4 - 8
10
°
C (50
°
F)
5.80 - 7.09k
Ω
110
°
C (230
°
F)
0.23 - 0.26k
Ω
WCIA0448E
Connector
Terminal
Temperature
Resistance
F30
4 - 8
10
°
C (50
°
F)
5.80 - 7.09k
Ω
110
°
C (230
°
F)
0.23 - 0.26k
Ω
WCIA0448E