![IBM TotalStorage 3494 Tape Library Operator'S Manual Download Page 511](http://html1.mh-extra.com/html/ibm/totalstorage-3494-tape-library/totalstorage-3494-tape-library_operators-manual_4097307511.webp)
Table
28.
Intervention-Required
Conditions
(continued)
Intervention-Required
Condition
Resolution
Actions
Message
OP0113
A
VTS
does
not
have
enough
available
physical
drives
(359x)
to
continue
operation.
(VTS
z)
Probable
Cause
Physical
tape
drives
of
type
359x
(where
x
will
be
either
″
0
″
or
″
2
″
depending
upon
tape
drive
type)
associated
with
VTS
z
have
become
unavailable
either
due
to
a
drive
failure
or
service
representative
action.
A
VTS
requires
a
minimum
of
two
available
physical
drives
for
operation.
Call
your
service
representative.
Message
OP0114
A
VTS
attempted
unsuccessfully
to
eject
a
stacked
volume
(xxxxxx)
during
disaster
recovery.
(VTS
z)
Probable
Cause
During
processing
of
a
physical
volume
during
disaster
recovery,
the
VTS
determined
that
the
physical
volume
was
damaged
and
attempted
to
place
the
volume
in
the
I/O
station,
but
the
attempt
failed.
The
likely
reason
is
that
the
cartridge
has
physical
damage
as
a
result
of
the
disaster,
and
it
interferes
with
the
cell
in
the
I/O
station.
Call
your
service
representative.
Message
OP0115
A
VTS
attempted
unsuccessfully
to
eject
a
damaged
stacked
volume
(xxxxxx).
(VTS
z)
Probable
Cause
During
the
last
usage
of
a
physical
volume,
the
VTS
subsystem
determined
that
the
volume
was
damaged
physically.
As
part
of
a
recovery
process,
an
attempt
was
made
to
eject
the
physical
volume
that
failed.
The
likely
reason
is
that
the
cartridge
has
physical
damage
as
a
result
of
the
disaster,
and
it
interferes
with
the
cell
in
the
I/O
station.
Call
your
service
representative.
Message
OP0116
VTS
physical
device
xxx
is
cabled
incorrectly.
It
has
been
made
unavailable.
(VTS
z)
Probable
Cause
During
the
installation
of
drive
xxx,
the
interface
cables
between
the
drive
and
the
Library
Manager
were
installed
incorrectly.
Call
your
service
representative.
Chapter
8.
Problem
Determination
Procedures
485
Summary of Contents for TotalStorage 3494 Tape Library
Page 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 2: ......
Page 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 14: ...xii 3494 Tape Library Operator Guide...
Page 22: ...xx 3494 Tape Library Operator Guide...
Page 72: ...46 3494 Tape Library Operator Guide...
Page 84: ...58 3494 Tape Library Operator Guide...
Page 124: ...98 3494 Tape Library Operator Guide...
Page 136: ...110 3494 Tape Library Operator Guide...
Page 150: ...124 3494 Tape Library Operator Guide...
Page 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Page 536: ...510 3494 Tape Library Operator Guide...
Page 572: ...546 3494 Tape Library Operator Guide...
Page 580: ...554 3494 Tape Library Operator Guide...
Page 600: ...574 3494 Tape Library Operator Guide...
Page 603: ......
Page 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Page 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...