Table
28.
Intervention-Required
Conditions
(continued)
Intervention-Required
Condition
Resolution
Actions
Message
OP0054
Volser
(xxxxxx)
cannot
be
removed
from
convenience
I/O
station.
Probable
Cause
The
cartridge
accessor
tried
several
times
to
remove
cartridge
xxxxxx
from
the
convenience
I/O
station
but
failed.
This
could
be
caused
by
a
problem
with
the
cartridge,
the
I/O
station,
the
gripper,
or
the
alignment
of
the
3494
Tape
Library.
1.
Remove
the
cartridge
from
the
convenience
I/O
station.
2.
Inspect
the
cartridge
and
cell
for
damage.
3.
Place
the
cartridge
in
the
convenience
I/O
station.
Message
OP0055
Free
storage
threshold
has
been
crossed
for
VTS
z.
Probable
Cause
The
available
free
space
in
VTS
z
has
crossed
the
threshold
set
through
the
Set
VTS
Management
Policies
window
on
the
Library
Manager.
1.
Insert
more
3590
or
3592
cartridges
into
the
library.
Ensure
that
their
volsers
are
within
the
range
of
stacked
volumes
defined
for
the
VTS
reporting
the
condition.
2.
The
VTS
Active
Data
window
for
the
VTS
is
updated
to
reflect
any
newly
added
stacked
volumes
on
the
hour.
Message
OP0056
A
volser
(xxxxxx)
with
an
unknown
media
type
has
been
left
in
the
convenience
input
station.
Probable
Cause
The
media-type
label
is
damaged.
1.
Remove
the
cartridge
from
the
convenience
I/O
station.
2.
Inspect
the
cartridge’s
seventh
character.
Install
the
correct
seventh
character
representing
the
media
type.
See
for
the
procedure.
3.
Place
the
cartridge
in
the
convenience
I/O
station.
Message
OP0057
A
volser
(xxxxxx)
with
an
unknown
media
type
has
been
left
in
the
high-capacity
input
station.
Probable
Cause
The
media-type
label
is
damaged.
1.
Place
the
3494
Tape
Library
in
Pause
mode.
2.
Open
the
enclosure.
3.
Remove
the
cartridge
from
the
high-capacity
input
rack.
4.
Inspect
the
cartridge’s
seventh
character.
Install
the
correct
seventh
character
representing
the
media
type.
See
for
the
procedure.
5.
Place
the
cartridge
in
the
convenience
I/O
station.
6.
Close
the
enclosure
door.
7.
Place
the
3494
Tape
Library
in
Auto
mode.
Message
OP0058
An
invalid
volser
(xxxxxx)
has
been
ejected
to
the
convenience
I/O
station.
Probable
Cause
Invalid
volsers
contain
leading
or
imbedded
blanks
or
invalid
characters.
Valid
characters
are
upper
case
A–Z
and
numerics
0–9.
1.
Remove
the
cartridge
from
the
convenience
I/O
station.
2.
Determine
why
the
cartridge
is
invalid
and
take
corrective
action.
474
3494
Tape
Library
Operator
Guide
Summary of Contents for TotalStorage 3494 Tape Library
Page 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 2: ......
Page 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 14: ...xii 3494 Tape Library Operator Guide...
Page 22: ...xx 3494 Tape Library Operator Guide...
Page 72: ...46 3494 Tape Library Operator Guide...
Page 84: ...58 3494 Tape Library Operator Guide...
Page 124: ...98 3494 Tape Library Operator Guide...
Page 136: ...110 3494 Tape Library Operator Guide...
Page 150: ...124 3494 Tape Library Operator Guide...
Page 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Page 536: ...510 3494 Tape Library Operator Guide...
Page 572: ...546 3494 Tape Library Operator Guide...
Page 580: ...554 3494 Tape Library Operator Guide...
Page 600: ...574 3494 Tape Library Operator Guide...
Page 603: ......
Page 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Page 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...