Table
25.
DFSMS
Messages
Based
on
Library
Failure
or
Exception
Conditions
(continued)
Resulting
Console
Message
Action
CBR3727I
Control
Unit
and
Library
Manager
incompatible
in
library
library-name
,
error
code
error-code
.
During
processing
of
a
request
in
library
library-name
,
it
was
determined
that
the
tape
control
unit
and
the
Library
Manager
are
at
incompatible
software
levels.
Error
code
error-code
indicates
the
nature
of
the
incompatibility.
1.
If
another
tape
subsystem
is
in
the
3494
Tape
Library,
vary
the
drives
associated
with
the
failed
subsystem
offline
and
resubmit
the
request
or
job.
2.
Call
your
service
representative.
CBR3728I
Volume
volser
in
use
in
library
library-name
.
{Already
mounted|Mount
pending|Eject
in
progress|Eject
pending|Export
in
progress}.
The
3494
cannot
process
a
request
for
a
3494
Tape
Library
operation
with
volume
volser
because
the
volume
is
already
in
use
in
the
3494
Tape
Library.
One
of
the
following
situations
is
present:
v
The
volume
is
already
mounted
on
another
drive.
v
A
mount
request
for
the
volume
is
pending.
v
The
volume
is
being
ejected
from
the
3494
currently.
v
An
eject
request
is
pending.
v
The
volume
is
being
exported.
1.
Determine
why
the
volume
is
already
in
use.
2.
Resubmit
the
3494
Tape
Library
request
when
the
volume
is
no
longer
in
use.
CBR3729I
Library
Manager
for
library
library-name
offline.
A
3494
Tape
Library
request
was
issued
to
library
library-name
,
but
the
Library
Manager
is
offline.
Possible
causes
are:
v
The
Library
Manager
is
powered-off.
v
The
Library
Manager
is
still
in
the
process
of
initialization.
v
The
Library
Manager
state
is
set
to
Offline.
1.
Check
that
the
Library
Manager
is
powered-on
and
the
Operator
menu
is
active.
2.
Check
the
Library
manager
field
of
the
System
Summary
window.
It
should
indicate
Online
.
3.
If
it
does
not
indicate
Online
,
use
the
Mode
window
and
place
the
library
in
the
Online
state.
If
the
3494
Tape
Library
does
not
go
to
the
Online
state,
call
your
service
representative.
4.
Vary
the
3494
Tape
Library
online
at
the
host
console.
5.
Resubmit
the
request
or
job.
CBR3750I
Message
from
library
library-name
:
message
.
The
operator
at
library
library-name
has
sent
message
message
to
all
connected
hosts.
Messages
can
be
sent
automatically
from
a
VTS
subsystem
that
is
performing
Export
or
Import
operations
to
post
operation
progress.
If
enabled
at
the
3494
Tape
Library
(see
text
messages
also
surface
for
operator
interventions
that
occur
at
the
3494.
See
for
the
complete
text
associated
with
each
numbered
intervention
message.
Handle
the
operator
intervention
as
required.
Chapter
8.
Problem
Determination
Procedures
445
Summary of Contents for TotalStorage 3494 Tape Library
Page 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 2: ......
Page 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 14: ...xii 3494 Tape Library Operator Guide...
Page 22: ...xx 3494 Tape Library Operator Guide...
Page 72: ...46 3494 Tape Library Operator Guide...
Page 84: ...58 3494 Tape Library Operator Guide...
Page 124: ...98 3494 Tape Library Operator Guide...
Page 136: ...110 3494 Tape Library Operator Guide...
Page 150: ...124 3494 Tape Library Operator Guide...
Page 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Page 536: ...510 3494 Tape Library Operator Guide...
Page 572: ...546 3494 Tape Library Operator Guide...
Page 580: ...554 3494 Tape Library Operator Guide...
Page 600: ...574 3494 Tape Library Operator Guide...
Page 603: ......
Page 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Page 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...