28.
Intervention-Required
Conditions
(continued)
Intervention-Required
Condition
Resolution
Actions
Message
OP0034
A
mislabeled
cleaner
cartridge
has
been
left
in
device
xxx
feed
slot.
Remove
the
cartridge.
Probable
Cause
During
a
Clean
operation,
tape
drive
xxx
determined
that
the
cleaner
cartridge
is
not
compatible
but
was
not
able
to
unload
the
cartridge.
It
is
likely
that
the
cartridge
has
a
missing
or
damaged
media-type
label,
or
the
media-type
label
is
incorrect
for
the
cartridge’s
media
type.
1.
Place
the
3494
Tape
Library
in
Pause
mode.
2.
Open
the
appropriate
enclosure
door.
3.
If
the
cartridge
is
accessible,
remove
it.
4.
If
the
cartridge
is
in
a
3490E
tape
drive,
make
the
tape
drive
not
ready
by
pressing
the
Ready
switch,
press
the
Unload
switch
to
unload
the
cartridge,
remove
the
cartridge,
then
make
the
tape
drive
ready
by
pressing
the
Ready
switch.
If
the
cartridge
is
in
a
3590
B1A,
E1A,
or
H1A
tape
drive,
select
the
Unload
option
in
the
Options
window,
press
Enter
,
then
remove
the
cartridge.
If
you
cannot
remove
the
cartridge,
call
your
service
representative.
5.
Close
the
enclosure
door.
6.
Place
the
3494
Tape
Library
in
Auto
mode.
7.
Inspect
the
cartridge’s
seventh
character.
Install
the
correct
seventh
character
representing
the
media
type.
See
the
tape
drive
Operator
Guide
for
the
procedure.
8.
Place
the
cartridge
in
the
convenience
I/O
station.
Message
OP0035
A
recoverable
error
occurred
on
device
xxx.
A
service
call
may
be
needed
if
the
error
persists.
Probable
Cause
Tape
device
xxx
recovered
from
a
failure
to
load
or
unload
a
tape
cartridge.
A
service
call
may
be
needed
if
the
error
persists.
Message
OP0036
A
mislabeled
cleaner
cartridge
has
been
ejected
to
the
convenience
I/O
station.
Probable
Cause
An
attempt
was
made
to
a
clean
a
tape
drive,
but
the
cartridge
was
determined
to
be
a
data
cartridge,
not
a
cleaner
cartridge.
One
of
the
following
conditions
caused
the
problem:
v
The
cartridge
was
labeled
mistakenly
with
an
external
volser
that
falls
within
the
range
of
volsers
designated
for
cleaner
volumes
in
the
3494
Tape
Library.
v
The
ranges
set
in
the
library
conflict
with
ranges
already
in
use
for
data
cartridges.
1.
Remove
the
cartridge
from
the
convenience
I/O
station.
2.
Determine
if
the
volser
on
the
cartridge
is
included
in
the
ranges
of
volsers
defined
for
cleaner
cartridges
by
selecting
the
Cleaner
Masks
option
in
the
Commands
window
on
the
Library
Manager
console.
3.
Either
correct
the
cleaner
masks
or
relabel
the
cartridge.
468
3494
Tape
Library
Operator
Guide
Summary of Contents for TotalStorage 3494 Tape Library
Page 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 2: ......
Page 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 14: ...xii 3494 Tape Library Operator Guide...
Page 22: ...xx 3494 Tape Library Operator Guide...
Page 72: ...46 3494 Tape Library Operator Guide...
Page 84: ...58 3494 Tape Library Operator Guide...
Page 124: ...98 3494 Tape Library Operator Guide...
Page 136: ...110 3494 Tape Library Operator Guide...
Page 150: ...124 3494 Tape Library Operator Guide...
Page 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Page 536: ...510 3494 Tape Library Operator Guide...
Page 572: ...546 3494 Tape Library Operator Guide...
Page 580: ...554 3494 Tape Library Operator Guide...
Page 600: ...574 3494 Tape Library Operator Guide...
Page 603: ......
Page 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Page 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...