Table
28.
Intervention-Required
Conditions
(continued)
Intervention-Required
Condition
Resolution
Actions
Message
OP0037
A
mislabeled
cleaner
cartridge
has
been
ejected
to
the
high-capacity
output
station.
Probable
Cause
An
attempt
was
made
to
a
clean
a
tape
drive,
but
the
cartridge
was
determined
to
be
a
data
cartridge,
not
a
cleaner
cartridge.
The
convenience
I/O
station
is
either
not
installed,
is
full,
or
is
unavailable.
The
cartridge
is
in
the
high-capacity
output
station.
One
of
the
following
conditions
caused
the
problem:
v
The
cartridge
was
labeled
mistakenly
with
an
external
volser
that
falls
within
the
range
of
volsers
designated
for
cleaner
volumes
in
the
3494.
v
The
ranges
set
in
the
3494
Tape
Library
conflict
with
ranges
already
in
use
for
data
cartridges.
1.
Place
the
library
system
in
Pause
mode.
2.
Open
the
appropriate
enclosure
door.
3.
Remove
the
cartridge
from
the
high-capacity
facility.
4.
Close
the
enclosure
door.
5.
Place
the
library
system
in
Auto
mode.
6.
Determine
if
the
volser
on
the
cartridge
is
included
in
the
ranges
of
volsers
defined
for
cleaner
cartridges
by
selecting
the
Cleaner
Masks
option
in
the
Commands
window
on
the
Library
Manager
console.
7.
Either
correct
the
cleaner
masks
or
relabel
the
cartridge.
Message
OP0039
A
duplicate
Volser
has
been
found
at
cell
yyyy.
Probable
Cause
During
an
Inventory
or
Inventory
Update
operation,
a
cartridge
was
found
whose
external
volume
serial
number,
xxxxxx,
is
the
same
as
that
of
another
cartridge
in
the
3494
Tape
Library.
The
cartridge
was
left
in
the
cell
where
it
was
found.
The
3494
Tape
Library
does
not
support
more
than
one
cartridge
with
the
same
volume
serial
number.
A
convenience
I/O
station
is
either
not
installed,
is
full,
or
is
unavailable,
and
a
high-capacity
output
station
has
not
been
defined.
1.
Place
the
3494
Tape
Library
in
Pause
mode.
2.
Open
the
appropriate
enclosure
door.
3.
Remove
the
cartridge
from
the
rack
cell
position
yyyy.
4.
Close
the
enclosure
door.
5.
Place
the
3494
Tape
Library
in
Auto
mode.
6.
Determine
why
the
cartridge
is
a
duplicate
and
take
corrective
action.
7.
Reinsert
the
cartridge
into
the
3494
Tape
Library
through
available
facilities.
Message
OP0040
The
cartridge
label
located
at
cell
yyyy
is
unreadable.
Probable
Cause
During
an
Inventory
or
Inventory
Update
operation,
the
vision
system
was
not
able
to
read
the
external
volume
serial
number
label
on
the
cartridge
in
cell
yyyy.
The
label
may
not
have
been
installed
correctly,
is
damaged,
or
is
not
one
of
the
supported
label
types.
A
convenience
I/O
station
is
either
not
installed,
is
full,
or
is
unavailable,
and
a
high-capacity
output
station
has
not
been
defined.
1.
Place
the
3494
Tape
Library
in
Pause
mode.
2.
Open
the
appropriate
enclosure
door.
3.
Remove
the
cartridge
from
the
rack
cell
position
yyyy.
4.
Close
the
enclosure
door.
5.
Place
the
3494
Tape
Library
in
Auto
mode.
6.
Determine
why
the
cartridge
label
is
unreadable
and
take
corrective
action.
7.
Reinsert
the
cartridge
into
the
3494
Tape
Library
through
available
facilities.
Chapter
8.
Problem
Determination
Procedures
469
Summary of Contents for TotalStorage 3494 Tape Library
Page 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 2: ......
Page 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Page 14: ...xii 3494 Tape Library Operator Guide...
Page 22: ...xx 3494 Tape Library Operator Guide...
Page 72: ...46 3494 Tape Library Operator Guide...
Page 84: ...58 3494 Tape Library Operator Guide...
Page 124: ...98 3494 Tape Library Operator Guide...
Page 136: ...110 3494 Tape Library Operator Guide...
Page 150: ...124 3494 Tape Library Operator Guide...
Page 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Page 536: ...510 3494 Tape Library Operator Guide...
Page 572: ...546 3494 Tape Library Operator Guide...
Page 580: ...554 3494 Tape Library Operator Guide...
Page 600: ...574 3494 Tape Library Operator Guide...
Page 603: ......
Page 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Page 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...