Warning Alarm Error Fault Description
Reason analysis
A.14
E.14*
Earth fault
Discharge f rom output phases
to ground(22KW and below)
E.16*
Short Circuit
Short circuit in motor or on
motor terminals.
A.17
E.17
Control Word
Timeout
Drive communication timeout,
this alarm occurs when C08.04
is set to 0 or 5.
A.24
E.24
Fan Fault
Too much dust on the fan or
the fan is aging.
E.25*
Brake resistor
short-circuit
Brake resistor is short circuit,
leading the brake f unction
invalid.
E.27
Brake transisitor
short-circuit
Brake transistor is short circuit
leading brake f unction invalid.
E.28
Brake Detect
Brake resistor is not connected
or working.
E.30*
Motor phase U
missing
Motor phase U is missing,
check the phase.
E.31*
Motor phase V
missing
Motor phase V is missing,
check the phase.
E.32*
Motor phase W
missing
Motor phase W is
missing,check the phase.
E.38*
Internal Fault
Contact the local distributor or
Holip Company.
A.59
Current Limit
Current exceeds value set in
C04.18.
A.61
E.61
Feedback Error Feedback signal is out of range.
A.66
Heat sink low
temperature
Temperature may be damaged.
A.69
E.69*
Power Card
Temp.
Power card is over
temperature.
A.79
E.79
Unde
fi
ned fault
Contact local distributor or
Holip Company.
E.80
Parameter
Initialization
Make parameter initialized.
Er.84
LCP Connection
with the inverter
failed
No communication between
LCP and the inverter.
Er.85
Button is
disabled
Refer to parameter group