HLP-C100 Series Operating Manual
HLP-C100 Series
-
4
-
Chapter 2 Standards and Speci
fi
cations
2.1 Label Description
Signi
fi
cance of the type code:
1-8
HLP-C100 Indicate Product Series
9-12
0D37 Indicate 0.37KW
13-14
21 Indicate 1-Phase AC 220V
23 Indicate 3-Phase AC 220V
43 Indicate 3-Phase AC 380V
15-17
P20 IP rating is 20
18 X Without AC choke
A With AC choke
19 X Without Brake unit
B With Brake unit
20 X Without DC choke
B With DC choke
21
1 Control panel with LED display and potentiometer
22 C With coating on PCB
23 X Reserved
24
0 Domestic sale
1 Overseas sale
25 A Without RS485
B With RS485
26-27
XX Reserved
28-31
VXXX Indicate sof tware version number, such as
V235 means the version number is 2.35 .