HLP-C100 Series
HLP-C100 Series Operating Manual
-
5
-
2.2 Particular Speci
fi
cations
2.3 Technical Speci
fi
cations
Model
Input voltage
Input
current/
A
Output
current/
A
Rated
power/
KW
Suitable
motor/
KW
Net
weight/
KG
HLP-C1000D3721 1×200-240V50/60HZ
6.1
2.2
0.37
0.37
0.84
HLP-C1000D7521 1×200-240V50/60HZ
11.6
4.2
0.75
0.75
0.84
HLP-C10001D521 1×200-240V50/60HZ
18.7
6.8
1.5
1.5
0.84
HLP-C1000D3723 3×200-240V50/60HZ
3.5
2.2
0.37
0.37
0.84
HLP-C1000D7523 3×200-240V50/60HZ
6.7
4.2
0.75
0.75
0.84
HLP-C10001D523 3×200-240V50/60HZ
10.9
6.8
1.5
1.5
0.84
HLP-C1000D7543
3×380-440V50/60HZ
3.5
2.2
0.75
0.75
0.84
3×440-480V50/60HZ
3.0
2.1
HLP-C10001D543
3×380-440V50/60HZ
5.9
3.7
1.5
1.5
0.84
3×440-480V50/60HZ
5.1
3.4
HLP-C10002D243
3×380-440V50/60HZ
8.5
5.3
2.2
2.2
0.84
3×440-480V50/60HZ
7.3
4.8
Item
Speci
fi
cation
Power supply
Supply voltage
single/three phase 220V ±20%;
three phase 380V ±20%;
Frequency
48-62Hz;
Max. imbalance
3%;
Motor output
Output voltage
three phase 0-100% of supply voltage;
Output
f requency
0-400Hz
Main control
f unctions
Control mode
V/F
Start torque
0.5Hz 150%;
Overload capacity 150% rated output current (60s)
PWM switch
f requency
2K-16KHz
Speed setting
resolution
Digital: 0.001Hz; analogy: 0.5‰ of the
max. operating f requency ;
Control
command source
LCP , digital terminal, local bus;
Frequency setting
source
LCP , analog, local bus;
Ramp control
Selectable 8-speed steps;