HLP-C100 Series Operating Manual
HLP-C100 Series
-
32
-
Item
Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ra
m
ete
r G
rou
p 1
6: D
ata
Re
ad
ou
ts
C16.00 Control Word
0~65535
C16.01
Reference
[Unit]
-4999.000~4999.000
C16.05
Motor Speed
[RPM]
0~9999
Hz
C16.10
Power[KW]
0.000~1000.000
kW
C16.12
Motor Voltage 0.0~65535
V
C16.13
Frequency
0.0~400.0
Hz
C16.14
Motor Current 0.00~655.35
A
C16.30
DC Link
Voltage
0~65535
V
C16.34
Heat sink Temp. 0~255
℃
C16.52
Feedback #
[Unit]
-4999.000~4999.000
C16.60
Digital Input
0~65535
C16.62
Analog Input
VI
0.000-20.000
V/
mA
C16.71
Relay Output
[bin]
0~65535
C16.86
FC Port REF
-32768~32767
C16.90
Alarm Word
0~0xFFFFFFFFUL
C16.91
Alarm Word 2 0~0xFFFFFFFFUL
C16.92
Warning Word 0~0x7FFFFFFFUL
C16.93
Warning Word
2
0~0x7FFFFFFFUL
Note:
Reference signed with “*”in parameter No. column means this parameter
can’t be modi
fi
ed when the motor is running. In factory setting column,
“*” means the default setting for this parameter is determined by the
drive type.