HLP-C100 Series
HLP-C100 Series Operating Manual
-
55
-
value by the percentage set in par. C03.12;
[34] Ramp bit0
、
bit0
、
bit1
、
bit2 used for select acceleration or
deceleration;
[35] Ramp bit1, same as [34] ;
[36] Ramp bit2, same as [34] ;
C05.40
Function Description
Range
Unit
Default Setting
Relay Function
0~55
5
C05.4* Relay
Option: [0]No operation;
[5]Drive running, Motor is running;
[9]Alarm. Frequency converter alarms;
[10]Alarm or warning. An alarm or warning occurs;
[15]Beyond f requency range. Output f requency beyond range set in
C04.52 and C04.53;
[16]Below f requency, low. Output f requency is lower than value set in
C04.52;
[17]Above f requency,high. Output f requency is higher than value set in
C04.53;
[21] Thermal warning. A thermal warning occurs;
[24]Ready-Voltage OK. Frequency converter is ready for operation,
main voltage is within speci
fi
ed voltage range;
[25] Reverse. Motor runs in counter clockwise;
[26] Bus OK. Local bus communication is normal;
[28] Brake-No warning. Brake is active, and no warnings are present;
[53]No alarm. Frequency converter is running normally, no alarm;
[55]Running reverse. Drive runs in counter clockwise;
Function: Enter VI Low Voltage corresponding to Min. reference/feedback set
in C06.14.
7.7 Parameter Group 06: Analog In/Out
C06.10
Function Description
Range
Unit Default Setting
Terminal VI Low Voltage 0.00~9.99
V
0.07
C06.1* Analoge Input 1