HLP-C100 Series Operating Manual
HLP-C100 Series
-
24
-
Item
Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
C01.72 Start Function
0: DC hold/delay
time; 2: Coast/Delay
time;
2
*C01.73 Flying start
0:Disabled; 1:Enabled;
0
C01.80
Function at
Stop
0: Coast; 1: DC Hold;
0
C01.82
Min Speed for
Function at
Stop [Hz]
0.0~20.0
Hz
0.0
Pa
ra
m
ete
r G
ro
up
0
2: B
ra
ke
F
un
cti
on
C02.00
DC Hold
Current
0~150
%
50
C02.01
DC Brake
Current
0~150
%
50
C02.02
DC Braking
Time
0.0~60.0
s
10.0
C02.04
DC Brake Cut
In Frequency
0.0~400.0
Hz
0.0
C02.10 Brake Function
0: Off; 1: Resistor
brake; 2: AC brake;
0
C02.11
Brake Resistor
(ohm)
Dep.on motor date
Ω
*
C02.17
Over-voltage
Control
0: Disabled;
2: Enabled;
0
Pa
ra
m
ete
r G
ro
up
0
3: R
ef
er
en
ce
/R
am
ps
C03.03
Maximum
Reference
0.000~4999.000
50.000
C03.07
Actual
reference
calculation
0: Preset ref
Reference source 1,2
1: Preset reference
priority
0
C03.10
Preset
Reference
-100.00~100.00
%
0.00
C03.11
Jog Speed [Hz] 0.0~400.0
Hz
5.0
C03.12
Catch up/slow
Down Value
0.00~100.00
%
0.00